COLD GROUP ON "OVERLAPPING" AP200T-3D-R2
Unit width 710 mm.
Cooling capacity rendered 3325 (W/f) for chamber volume 45,6 m³ / 45 600 Lit. (T° internal 0° C & T° external +32° C).
Refrigerant expansion by capillary.
"Overlapping" refrigeration units.
Cooling capacity rendered 3325 (W/f) for chamber volume 45,6 m³ / 45 600 Lit. (T° internal 0° C & T° external +32° C).
Refrigerant expansion by capillary.
"Overlapping" refrigeration units.
Manufacturer: DIAMOND
Available in:
2-3 days
Dimensions (mm):
710 x 430/1254 x 828
Temperature (°C):
-5°+5°
Power (kW):
1,9
Weight (kg):
154
Power supply:
400/3N 50Hz
Volume (m3):
1,17
Base price 3 365 €
Salesprice with discount
Sales price 4 072 €
Price / kg:
Product description
COLD GROUP ON "OVERLAPPING" AP200T-3D-R2
- Unit width 710 mm.
- Cooling capacity rendered 3325 (W/f) for chamber volume 45,6 m³ / 45 600 Lit. (T° internal 0° C & T° external +32° C).
- Refrigerant expansion by capillary.
- "Overlapping" refrigeration units.
- Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).
- All units are supplied as standard with a high pressure switch and KVL valve.
- Automatic hot gas defrost with self-evaporation and overflow.
- The evaporator drain pipe is equipped with a resistor to prevent ice formation.
- Refrigerant gas R290.
- Supplied with cables and micro-switch for door and light (Porthole lights supplied as standard).
- Microprocessor control with touch-sensitive keys.
- Caution: as standard, the ideal ambient operating temperature cannot be lower than 5°C.
- When installed outdoors, the unit must be protected from the elements.
PLUS:
- Can be placed on any of our chambers (minimum 600mm panel).
- All units are supplied as standard with a high-pressure switch.
- All units are fitted with a thermostatic valve.