REFRIGERANT GROUP BY-BLOCK    HN120M-1Q

REFRIGERANT GROUP BY-BLOCK    HN120M-1QREFRIGERANT GROUP BY-BLOCK    HN120M-1Q
REFRIGERANT GROUP BY-BLOCK    HN120M-1Q
003-TUYAUX-big97
004--big3
006-nh120m-1q-big2
002-HP50M-1M-big4
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C). Refrigerant expansion by thermostatic valve.
Manufacturer: DIAMOND
Available in:
2-3 days
Dimensions (mm):
700&666 x 490&433 x 380&188
Temperature (°C):
-15° -25°
Power (kW):
0,64
Power supply:
230/1N 50Hz
Weight (kg):
51
Volume (m3):
0,58
Base price 2 680 €
Salesprice with discount
Sales price 3 243 €
Price / kg:
Log in

Register



 Print product Recommend a friend
Product description

REFRIGERANT GROUP BY-BLOCK    HN120M-1Q

  • Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).
  • Refrigerant expansion by thermostatic valve.
  • The low temperature units (HN) are supplied with a cable for the connection of the door resistor.
  • Bi-block" refrigeration units.
  • Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...
  • Delivered with 2 wall brackets as standard. 
  • Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).
  • All units are supplied as standard with a high pressure switch and KVL valve, as well as cables for door and light microswitches.
  • Control panel with separate touch-sensitive keys, connected to the unit by a 10 m cable
  • Automatic defrosting by electric resistance, water flow located below the evaporator. The evaporator drain pipe is equipped with a resistance to prevent ice formation.
  • Unit certified in climatic class 5 (40°C Temperature - 40% Humidity). 
  • Refrigerant gas R452a.
  • Window lights delivered as standard with micro-switch for door.

ATTENTION:

  • As standard, the ideal ambient operating temperature must not be lower than 10°C. If this is not the case, you must provide compressor preheating (H-PR-R), a pressure switch for the condenser fan (H-PVC-R) and a heated electrical panel (H-TEC-R).
  • In this case, the operating temperature cannot be lower than -5°C.

PLUS:

  • Easily removable panels for easy access in case of intervention.
  • Defrosting by electric resistance.
  • All units are supplied with a high pressure switch as standard.
  • The negative units are equipped with a thermostatic valve.